FOUR SEASONS 39430
|
|
$18.45
Precio
|
$0.00
Depósito
|
+ Vendido en Paquetes de 1x1
Empacar
|
$18.45
Total
|
|
|
|
Especificaciones de FOUR SEASONS 39430 |
---|
Color | Aluminio | Descripción | Expansión Válvulas | Liquido Entrada Género | Hembra | Liquido Entrada Tamaño | Número 6 | Liquido Entrada Tamaño | 0.4 pulg. | Liquido Entrada Tamaño | 10.15 mm | Liquido Entrada Estilo | Capturado | Liquido Rosca de Entrada | No Roscado | Liquido Entrada Tipo | Junta Tórica | Liquido Salida Género | Hembra | Liquido Tamaño de la Salida | Número 10 | Liquido Salida Estilo | Capturado | Liquido Salida Rosca | No Roscado | Liquido Salida Tipo | Junta Tórica | Lqd Out Size | 0.61 pulg. | Lqd Out Size | 15.5 mm | Material | Aluminio | Agujero de montaje Cantidad | 2 | Junta Tórica A Número/Descripción | 24611 / Verde Junta Tórica | Junta Tórica A Cantidad | 1 | Junta Tórica B Número/Descripción | 24661 / Verde Junta Tórica | Junta Tórica B Cantidad | 1 | Junta Tórica C Número/Descripción | 24681 / Verde Junta Tórica | Junta Tórica C Cantidad | 2 | Estilo | sin Solenoide | Suc In Size | 0.72 pulg. | Suc In Size | 18.3 mm | Suc Out Gender | Hembra | Suc Out Size | 0.72 pulg. | Suc Out Size | 18.3 mm | Suc Out Trd | No Roscado | Succión Entrada Género | Hembra | Succión Entrada Tamaño | Número 12 | Succión Entrada Estilo | Capturado | Succión Rosca de Entrada | No Roscado | Succión Entrada Tipo | Junta Tórica | Succión Tamaño de la Salida | Número 12 | Succión Salida Estilo | Capturado | Succión Salida Tipo | Junta Tórica | Super Calor | -1.500 | Interruptor Incluido? | NO Incluido | Tonnage | 1.5 | Tipo | Bloque Tipo |
|
|
Four Seasons' expansion devices are specifically calibrated to provide proper flow to the evaporator as well as restricting or modulating high pressure liquid causing a pressure drop to lower the refrigerant temperature. They also provide optimum cabin comfort for both the driver and passengers.
Features & Benefits
- Block Valves are aluminum construction; all internal parts are designed to OE specifications
- Internally and Externally Equalized Valves are copper and brass construction
- Tubes to Cap connections are double soldered to insure integrity
- Coverage includes both forward and reverse flow designs
- Tonnage and Superheat is matched to OE specifications
- Power valve is seasoned for 30 days, assembled and 100% function tested prior to shipping
Why Replace?
Expansion Valves regulate refrigerant flow within the system. Other than the Compressor, this is the only other moving part in the system.
- Expansion Valves can become contaminated with system debris
- Expansion Valves cannot be flushed and should be replaced whenever the Compressor is replaced
Adicional Recursos ¿Por qué limpiar o cambiar la válvula de expansión?
Atención Clientes de California - Advertencia: Este producto contiene un químico conocido en el estado de California que causa cáncer y defectos de nacimiento u otros daños reproductivos.
|
Fabricante Original de Equipo / Números de Intercambio: 80221T0AA01, 80221TS8A01, 80221TS8A02 |
Información de Garantía:120 días |
|